Transit: Rectangular Frame

In the picture the first end of the segment is labeled FRONT.

Catalog DBF FieldDescriptive Field NameDescription
CLASSCLASSMust be set to TRANSIT.
WIDTHWIDTHThe overall width of the transit.
HEIGHTHEIGHTThe overall height of the transit.
LENGTHLENGTHThe length (depth) of the transit.
RADIUSRADIUSMust be empty (otherwise will be considered a circular transit).
WIDTH1OPENINGS ACROSSThe number of openings in the horizontal axis (for example, 3 in the image above).
HEIGHT1OPENINGS DOWNThe number of openings in the vertical axis (for example, 2 in the image above).
WIDTH2FLANGE WIDTHThe width of the transit flange (if present).
HEIGHT2FLANGE HEIGHTThe height of the transit flange (if present).
LENGTH2FLANGE THICKNESSThe thickness of the transit flange (if present).
WIDTH3PACKING WIDTHThe width available for sealing blocks in each opening.
HEIGHT3PACKING HEIGHTThe height available for sealing blocks in each opening (excluding the height of any compression wedge module).
HEIGHT4WEDGE HEIGHTThe height of the compression wedge module (if the transit does not feature integrated compression).
WIDTH5DIVIDER WIDTHThe width of the vertical divider between openings (if there is more than one opening on the horizontal axis).
HEIGHT5DIVIDER HEIGHTThe height of the horizontal divider between openings (if there is more than one opening on the horizontal axis).

See also

Transits Overview

General Component Attributes