T-Section: Duct, Tray, Trench

In the picture the first end of the segment is at the bottom-left.

Catalog DBF FieldDescriptive Field NameDescription
CLASSCLASSMust be set to DUCTT, TRAYT, or TRENCHT.
HEIGHTHEIGHTThe height of the T Section.
WIDTHWIDTHThe width of the straight part of T Section.
SECWIDTHSECONDARY WIDTH

The width of the branching part of the T Section.

Smaller than WIDTH for a reducing T.

BNDRADIUSBEND RADIUSThe bend radius of the branch of the T Section
CNRANGLECORNER ANGLE

The angle in degrees that the T end of the segment makes to the straight path.

Values from 20.0 to 90.0 create a left-branching T.

Values from -20.0 to -90.0 create a right-branching T.

0.0 will be re-interpreted as 90.0, including older models where this dimension was not supported.

LENGTH1EXTENSION 1Straight extension at the first end.
LENGTH2EXTENSION 2Straight extension at the straight ahead end.
LENGTH3EXTENSION 3Straight extension at the branching end.
HEIGHT2BASE THICKNESSThe thickness of the base to the inner cavity.
WIDTH2SIDE WALL THICKNESSThe thickness of each wall to the inner cavity.