Electrical Design Software | Elecdes Design Suite by Scada Systems Ltd

Corner: Duct, Tray, Trench

In the picture the first end of the segment is at the bottom-left.

Catalog DBF FieldDescriptive Field NameDescription
CLASSCLASSMust be set to DUCTCNR, TRAYCNR, or TRENCHCNR.
HEIGHTHEIGHTThe height of the corner.
WIDTHWIDTHThe width of the corner.
BNDRADIUSBEND RADIUSThe radius to the inside edge of the corner.
CNRANGLECORNER ANGLE

The inside angle of the corner = ( 180° - deviation from straight ).

e.g. "150" for a corner that deviates 30° from straight.

HEIGHT2BASE THICKNESSThe thickness of the base to the inner cavity.
WIDTH2SIDE WALL THICKNESSThe thickness of each wall to the inner cavity.
LENGTH1EXTENSION 1Straight extension at the first end.
LENGTH2EXTENSION 2Straight extension at the second end.
LENGTH5UNTRIMMED CNRANGLE

The original inside angle of the segment before trimming to the required angle.

This value is set from the CNRANGLE field of the catalog item when it is inserted.

This field should be empty in a catalog record.