Electrical Design Software | Elecdes Design Suite by Scada Systems Ltd

X-Section: Duct, Tray, Trench

In the picture the first end of the segment is at the bottom-left.

Catalog DBF FieldDescriptive Field NameDescription
CLASSCLASSMust be set to DUCTX, TRAYX, or TRENCHX.
HEIGHTHEIGHTThe height of the X Section.
WIDTHWIDTHThe width of the X Section.
SECWIDTHSECONDARY WIDTH

The width of the perpendicular crossing part of the X Section.

Smaller than WIDTH for a reducing X.

BNDRADIUSBEND RADIUSThe radius of the inside edge of the corner.
LENGTH1EXTENSION 1Straight extension at both ends of the two straight ahead ends.
LENGTH2EXTENSION 2Straight extension at both ends of the perpendicular crossing ends.
HEIGHT2BASE THICKNESSThe thickness of the base to the inner cavity.
WIDTH2SIDE WALL THICKNESSThe thickness of each wall to the inner cavity.