The Panel Wire Network Schedule Format


The field structure for the wire network file, <ProjectName>WireNetwork.dbf, is as follows:

Field NameDefault WidthDescriptionSource
WIRE 25 Name given to wire marker attached to the conductor or default conductor name From WIRENAME attribute of wire marker OR generated internally
NETWORK 10 Number given to each physically connected set of line segments representing a wire (where continuation is ignored). Generated inside report function

TERMINALS

TERMINALSn

255

The terminals to which this wire is connected, in a comma separated list.

If required Ebase will add up to 8 further columns to the file to accommodate larger terminal lists. The columns will be named TERMINALSn where n is 2-8.

From attributes of device or terminal component at each termination
TYPE 15 Type of wire as given in the catalog, blank if default named wire From catalog if wire marker exists
SIZE 10 Size of wire as given in the catalog, blank if default named wire From catalog if wire marker exists
RATING 20 Rating of the wire as given in the catalog, blank if default named wire From catalog if wire marker exists
MANUF 25 Manufacturer name for wire, blank if default named wire From MFG attribute of wire marker if it exists
CATNO 50 Manufacturer's part number, blank if default named wire From CATNO attribute of wire marker if it exists
USER 55 User defined data From USER catalog field
PRICE 10 Price per unit length as given in the catalog, blank if default named wire From catalog if wire marker exists
DRUMSIZE 15 The length of wire contained in one whole drum. From catalog if wire marker exists
CABLEFACTR 10 A number representing the fill factor for this wire. Can be related to size, weight, thermal requirements etc. Zero, 0, is general and will not contribute to filling. From catalog if wire marker exists
WEIGHT 10 A number representing the weight fill factor for this wire. Zero, 0, is general and will not contribute to filling. From catalog if wire marker exists
POWER 5 A number representing the power rating for this wire. From catalog if wire marker exists
ZONECLASS 10 Area or zone classification. User defined for warnings and assistance for wire catalog's. From catalog if wire marker exists
DETAILS 30 The details of the wire User entered
WARNINGS 150 Wire schedule warnings Generated in function

Notes

  • When "only wire extension markers can be continuations" and join the networks of line segments that make up wires, a connected line segment network can be identified only by considering both the wirename (WIRE column) and network value (NETWORK column). This is as a result of the possible re-use of a wirename in a second panel under this system. See Conductor Naming and Continuation.

  • If a wire marker exists and the MFG and CATNO attributes do not reference a catalog entry, then Elecdes will not find the information on the wire details and the fields TYPE, SIZE and RATING will not contain any data.

  • If required Ebase will add up to 8 further TERMINALS columns to the file to accommodate larger terminal lists. The columns will be named TERMINALSn where n is 2-8.

See also

Customise Report Formats